What’s Vulnerable › Vulnerabilities
CVE-2013-5709
- Severity: high (CVSS 8.3 v2.0)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 3.0% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2013-09-17 · updated 2026-06-16
- Weakness: CWE-189
Description
The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value.
Affected products
- Siemens Scalance X-200: all versions
- Siemens Scalance X-200 Series Firmware: through 4.4; 4.3
- Siemens Scalance X-200Rna: all versions
- Siemens SCALANCE X200-4P IRT: all versions
- Siemens SCALANCE X201-3P IRT: all versions
- Siemens SCALANCE X202-2IRT: all versions
- Siemens SCALANCE X202-2P IRT: all versions
- Siemens SCALANCE X204IRT: all versions
- Siemens Scalance Xf-200: all versions
References
- http://ics-cert.us-cert.gov/advisories/ICSA-13-254-01
- http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-850708.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-850708.pdf
- http://ics-cert.us-cert.gov/advisories/ICSA-13-254-01
- http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-850708.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-850708.pdf
Get alerted when CVE-2013-5709 or the next vulnerability affects your stack