What’s Vulnerable › Vulnerabilities
CVE-2016-7090
- Severity: medium (CVSS 4.0 v3.0)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 1.9% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2016-09-29 · updated 2026-06-17
- Weakness: CWE-200
Description
The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session.
Affected products
- Siemens Scalance M-800 Firmware: through 4.01
- Siemens Scalance S615 Firmware: through 4.01
References
- http://www.securityfocus.com/bid/93115
- http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-342135.pdf
- https://ics-cert.us-cert.gov/advisories/ICSA-16-271-01
- http://www.securityfocus.com/bid/93115
- http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-342135.pdf
- https://ics-cert.us-cert.gov/advisories/ICSA-16-271-01
Get alerted when CVE-2016-7090 or the next vulnerability affects your stack