What’s Vulnerable › Vulnerabilities
CVE-2018-17916
- Severity: critical (CVSS 9.8 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 3.7% probability of exploitation in the next 30 days
- Public exploit or detection template: yes
- Published: 2018-11-02 · updated 2026-06-17
- Weakness: CWE-121
Description
InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. If InduSoft Web Studio remote communication security was not enabled, or a password was left blank, a remote user could send a carefully crafted packet to invoke an arbitrary process, with potential for code to be executed. The code would be executed under the privileges of the InduSoft Web Studio or InTouch Edge HMI runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Edge HMI server machine.
Affected products
- AVEVA Edge: 8.1, 8.1-sp1
- AVEVA Software, LLC InduSoft Web Studio: 6.1-sp5, 6.1-sp6_p3, 7.1, 7.1-sp1, 7.1-sp2, 7.1-sp3 (+21)
- AVEVA Intouch Machine Edition 2014: r2
References
- https://ics-cert.us-cert.gov/advisories/ICSA-18-305-01
- https://www.tenable.com/security/research/tra-2018-34
- https://ics-cert.us-cert.gov/advisories/ICSA-18-305-01
- https://www.tenable.com/security/research/tra-2018-34
Get alerted when CVE-2018-17916 or the next vulnerability affects your stack