What’s Vulnerable › Vulnerabilities
CVE-2018-3991
- Severity: critical (CVSS 9.8 v3.0)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 34.3% probability of exploitation in the next 30 days
- Public exploit or detection template: yes
- Published: 2019-02-05 · updated 2026-06-17
- Weakness: CWE-787
Description
An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TCP packet to trigger this vulnerability.
Affected products
- Siemens AG SIMATIC WinCC OA V3.14 and prior: 3.14, 3.15, 3.16
- WibuKey Runtime: 6.40.2402.500
References
- http://www.securityfocus.com/bid/107005
- https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf
- https://talosintelligence.com/vulnerability_reports/TALOS-2018-0659
- http://www.securityfocus.com/bid/107005
- https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf
- https://talosintelligence.com/vulnerability_reports/TALOS-2018-0659