What’s Vulnerable › Vulnerabilities
CVE-2019-18341
- Severity: medium (CVSS 5.0 v2.0)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 1.6% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2019-12-12 · updated 2026-06-17
- Weakness: CWE-287
Description
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability. A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).
Affected products
- Siemens Sinvr 3 Central Control Server: all versions
- Siemens Sinvr 3 Video Server: all versions
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf