What’s Vulnerable › Vulnerabilities
CVE-2020-15782
- Severity: critical (CVSS 9.8 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 5.2% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2021-05-28 · updated 2026-06-17
- Weakness: CWE-119
Description
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.
Affected products
- Siemens Et 200Sp Open Controller Firmware: all versions
- Siemens S7-1200 Cpu Firmware: before 4.5.0 — fixed in 4.5.0
- Siemens S7-1500 Cpu Firmware: before 2.9.2 — fixed in 2.9.2
- Siemens Simatic Driver Controller Firmware: before 2.9.2 — fixed in 2.9.2
- Siemens Simatic S7-1500 Software Controller: all versions
- Siemens SIMATIC S7-PLCSIM Advanced: before 4.0 — fixed in 4.0
How to fix
Upgrade to a fixed version: Siemens S7-1200 Cpu Firmware 4.5.0; Siemens S7-1500 Cpu Firmware 2.9.2; Siemens Simatic Driver Controller Firmware 2.9.2; Siemens SIMATIC S7-PLCSIM Advanced 4.0. Check the vendor advisory for mitigations.
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf
Get alerted when CVE-2020-15782 or the next vulnerability affects your stack