CVE-2020-8087
- Severity: critical (CVSS 9.8 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 6.3% probability of exploitation in the next 30 days
- Public exploit or detection template: yes
- Published: 2020-01-27 · updated 2026-06-17
- Weakness: CWE-20
Description
SMC Networks D3G0804W D3GNV5M-3.5.1.6.10_GA devices allow remote command execution by leveraging access to the Network Diagnostic Tools screen, as demonstrated by an admin login. The attacker must use a Parameter Pollution approach against goform/formSetDiagnosticToolsFmPing by providing the vlu_diagnostic_tools__ping_address parameter twice: once with a shell metacharacter and a command name, and once with a command argument.
Affected products
- Smc D3G0804W Firmware: d3gnv5m-3.5.1.6.10_ga
References
- https://sku11army.blogspot.com/2020/01/smc-networks-remote-code-execution.html
- https://sku11army.blogspot.com/2020/01/smc-networks-remote-code-execution.html