What’s Vulnerable › Vulnerabilities
CVE-2021-20587
- Severity: critical (CVSS 9.8 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 3.9% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2021-02-19 · updated 2026-06-17
- Weakness: CWE-122
Description
Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior, and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition on the software products, and possibly to execute a malicious code on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
Affected products
- Mitsubishielectric C Controller Module Setting And Monitoring Tool: all versions
- Mitsubishi Electric Corporation CPU Module Logging Configuration Tool: through 1.112r
- Mitsubishi Electric CW Configurator: through 1.011m
- Mitsubishi Electric Corporation Data Transfer: through 3.44w
- Mitsubishi Electric Corporation EZSocket: all versions
- Mitsubishi Electric Corporation FR Configurator: all versions
- Mitsubishi Electric Corporation FR Configurator2: through 1.24a
- Mitsubishi Electric Corporation FR Configurator SW3: all versions
- Mitsubishielectric Gt Designer3: through 1.250l
- Mitsubishielectric Gt Softgot1000: through 3.245f
- Mitsubishi Electric Corporation GT SoftGOT2000: through 1.250l
- Mitsubishi Electric Corporation GX Configurator-DP: through 7.14q
- Mitsubishi Electric Corporation GX Configurator-QP: all versions
- Mitsubishi Electric Corporation GX Developer: through 8.506c
- Mitsubishi Electric Corporation GX Explorer: all versions
- Mitsubishi Electric Corporation GX IEC Developer: all versions
- Mitsubishi Electric Corporation GX LogViewer: through 1.115u
- Mitsubishi Electric Corporation GX RemoteService-I: all versions
- Mitsubishi Electric Corporation GX Works2: through 1.597x
- Mitsubishi Electric Corporation GX Works3: through 1.070y
- Mitsubishielectric Iq Monozukuri Andon: all versions
- Mitsubishielectric Iq Monozukuri Process Remote Monitoring: all versions
- Mitsubishi Electric Corporation M_CommDTM-HART: all versions
- Mitsubishi Electric Corporation M_CommDTM-IO-Link: all versions
- Mitsubishi Electric Corporation MELFA-Works: through 4.4
- Mitsubishi Electric Corporation MELSEC WinCPU Setting Utility: all versions
- Mitsubishi Electric MELSOFT EM Software Development Kit: all versions
- Mitsubishi Electric Corporation MELSOFT Navigator: through 2.74c
- Mitsubishi Electric Corporation MH11 SettingTool Version2: through 2.004e
- Mitsubishi Electric MI Configurator: all versions
References
- https://jvn.jp/vu/JVNVU92330101
- https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02
- https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2020-021_en.pdf
- https://jvn.jp/vu/JVNVU92330101/index.html
- https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02
- https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf
Get alerted when CVE-2021-20587 or the next vulnerability affects your stack