CVE-2021-33842: Circutor SGE-PLC1000 improper authentication
- Severity: high (CVSS 8.8 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.4% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2021-06-09 · updated 2026-06-17
- Weakness: CWE-565
Description
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located.
Affected products
- Circutor SGE-PLC1000: 0.9.2b
References
- https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication
- https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication
Get alerted when CVE-2021-33842 or the next vulnerability affects your stack