What’s Vulnerable › Vulnerabilities
CVE-2022-0715
- Severity: critical (CVSS 9.1 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 5.8% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2022-03-09 · updated 2026-06-17
- Weakness: CWE-287
Description
A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
Affected products
- Schneider-Electric Scl Series 1029 Ups Firmware: through 02.5
- Schneider-Electric Scl Series 1030 Ups Firmware: through 02.5
- Schneider-Electric Scl Series 1036 Ups Firmware: through 02.5
- Schneider-Electric Scl Series 1037 Ups Firmware: through 03.1
- Schneider-Electric Smc Series 1005 Ups Firmware: through 14.1
- Schneider-Electric Smc Series 1007 Ups Firmware: through 11.0
- Schneider-Electric Smc Series 1018 Ups Firmware: through 04.2
- Schneider-Electric Smc Series 1041 Ups Firmware: through 01.1
- Schneider-Electric Smt Series 1015 Ups Firmware: through 04.5
- Schneider-Electric Smt Series 1031 Ups Firmware: through 03.1
- Schneider-Electric Smt Series 1040 Ups Firmware: through 01.2
- Schneider-Electric Smt Series 18 Ups Firmware: through 09.8
- Schneider-Electric Smtl Series 1026 Ups Firmware: through 02.9
- Schneider-Electric Smx Series 1031 Ups Firmware: through 03.1
- Schneider-Electric Smx Series 20 Ups Firmware: through 10.2
- Schneider-Electric Smx Series 23 Ups Firmware: through 07.0
- Schneider-Electric Srt Series 1001 Ups Firmware: through 05.1
- Schneider-Electric Srt Series 1002 Ups Firmware: through a05.2
- Schneider-Electric Srt Series 1010 Ups Firmware: through 08.3
- Schneider-Electric Srt Series 1013 Ups Firmware: through 05.1
- Schneider-Electric Srt Series 1014 Ups Firmware: through a05.2
- Schneider-Electric Srt Series 1019 Ups Firmware: through 08.3
- Schneider-Electric Srt Series 1020 Ups Firmware: through 10.4
- Schneider-Electric Srt Series 1021 Ups Firmware: through 12.2
- Schneider-Electric Srt Series 1025 Ups Firmware: through 08.3
- Schneider-Electric Srtl1000Rmxli-Nc Firmware: through 01.0
- Schneider-Electric Srtl1000Rmxli Firmware: through 01.0
- Schneider-Electric Srtl1500Rmxli-Nc Firmware: through 01.0
- Schneider-Electric Srtl1500Rmxli Firmware: through 01.0
- Schneider-Electric Srtl2200Rmxli-Nc Firmware: through 01.0
References
- https://www.se.com/ww/en/download/document/SEVD-2022-067-02/
- https://www.se.com/ww/en/download/document/SEVD-2022-067-02/
Get alerted when CVE-2022-0715 or the next vulnerability affects your stack