What’s Vulnerable › Vulnerabilities
CVE-2023-2187
- Severity: medium (CVSS 5.3 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.6% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2023-06-07 · updated 2026-10-23
- Weakness: CWE-306
Description
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event". Furthermore, an attacker could use this vulnerability to spam the logged-in user with false events.
Affected products
- Triangle MicroWorks SCADA Data Gateway: through 5.01.03
References
- https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html
- https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html
Get alerted when CVE-2023-2187 or the next vulnerability affects your stack