What’s Vulnerable › Vulnerabilities
CVE-2023-41032
- Severity: high (CVSS 7.8 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.2% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2023-09-12 · updated 2026-06-17
- Weakness: CWE-787
Description
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.253), Parasolid V35.1 (All versions < V35.1.184), Parasolid V36.0 (All versions < V36.0.142), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21263)
Affected products
- Siemens Parasolid: from 34.1 before 34.1.258; from 35.0 before 35.0.253; from 35.1 before 35.1.184; from 36.0 before 36.0.142 — fixed in 34.1.258, 35.0.253, 35.1.184, 36.0.142
- Siemens Simcenter Femap: from 2301.0 before 2301.0003; from 2306.0 before 2306.0001 — fixed in 2301.0003, 2306.0001
How to fix
Upgrade to a fixed version: Siemens Parasolid 34.1.258, 35.0.253, 35.1.184, 36.0.142; Siemens Simcenter Femap 2301.0003, 2306.0001. Check the vendor advisory for mitigations.
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf
- https://www.bentley.com/advisories/be-2023-0004/
- https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf
- https://www.bentley.com/advisories/be-2023-0004/