What’s Vulnerable › Vulnerabilities
CVE-2023-48427
- Severity: critical (CVSS 9.8 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.5% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2023-12-12 · updated 2026-06-17
- Weakness: CWE-295
Description
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected products do not properly validate the certificate of the configured UMC server. This could allow an attacker to intercept credentials that are sent to the UMC server as well as to manipulate responses, potentially allowing an attacker to escalate privileges.
Affected products
- Siemens SINEC INS: before 1.0; 1.0, 1.0-sp1, 1.0-sp2, 1.0-sp2_update_1 — fixed in 1.0
How to fix
Upgrade to a fixed version: Siemens SINEC INS 1.0. Check the vendor advisory for mitigations.
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf
Get alerted when CVE-2023-48427 or the next vulnerability affects your stack