What’s Vulnerable › Vulnerabilities
CVE-2024-20463: Cisco ATA 190 Series Analog Telephone Adapter Firmware Command Injection and Denial of Service Vulnerability
- Severity: high (CVSS 7.1 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.4% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2024-10-16 · updated 2026-06-17
- Weakness: CWE-305
Description
A vulnerability in the web-based management interface of Cisco ATA 190 Series Analog Telephone Adapter firmware could allow an unauthenticated, remote attacker to modify the configuration or reboot an affected device. This vulnerability is due to the HTTP server allowing state changes in GET requests. An attacker could exploit this vulnerability by sending a malicious request to the web-based management interface on an affected device. A successful exploit could allow the attacker to make limited modifications to the configuration or reboot the device, resulting in a denial of service (DoS) condition.
Affected products
- Cisco Ata 191 Firmware: before 12.0.2; before 11.2.5 — fixed in 11.2.5, 12.0.2
- Cisco Ata 192 Firmware: before 11.2.5 — fixed in 11.2.5
How to fix
Upgrade to a fixed version: Cisco Ata 191 Firmware 11.2.5, 12.0.2; Cisco Ata 192 Firmware 11.2.5. Check the vendor advisory for mitigations.
References
Get alerted when CVE-2024-20463 or the next vulnerability affects your stack