What’s Vulnerable › Vulnerabilities

CVE-2024-8956: PTZOptics PT30X-SDI/NDI Cameras Authentication Bypass Vulnerability

Description

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.

Affected products

How to fix

Upgrade to a fixed version: PTZOptics Pt30X-Ndi-Xx-G2 Firmware 6.3.40; PTZOptics Pt30X-Sdi Firmware 6.3.40. Check the vendor advisory for mitigations.

References

Get alerted when CVE-2024-8956 or the next vulnerability affects your stack