CVE-2025-1851: Tenda AC7 SetFirewallCfg formSetFirewallCfg stack-based overflow
- Severity: high (CVSS 8.8 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 1.1% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2025-03-03 · updated 2026-06-17
- Weakness: CWE-119
Description
A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Affected products
- Tenda AC7: before 15.03.06.44 — fixed in 15.03.06.44
How to fix
Upgrade to a fixed version: Tenda AC7 15.03.06.44. Check the vendor advisory for mitigations.
References
- https://github.com/Raining-101/IOT_cve/blob/main/ac7_V15.03.06.44_SetFirewallCfg.md
- https://vuldb.com/?ctiid.298119