What’s Vulnerable › Vulnerabilities
CVE-2025-40567
- Severity: medium (CVSS 6.5 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.4% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2025-06-10 · updated 2026-06-17
- Weakness: CWE-863
Description
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Rollback" functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to make the affected product roll back configuration changes made by privileged users.
Affected products
- Siemens RUGGEDCOM RST2428P: before V3.2 — fixed in V3.2
- Siemens SCALANCE XCH328: before V3.2 — fixed in V3.2
- Siemens SCALANCE XCM324: before V3.2 — fixed in V3.2
- Siemens SCALANCE XCM328: before V3.2 — fixed in V3.2
- Siemens SCALANCE XCM332: before V3.2 — fixed in V3.2
- Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC): before V3.2 — fixed in V3.2
- Siemens SCALANCE XRM334 (230 V AC, 12xFO): before V3.2 — fixed in V3.2
- Siemens SCALANCE XRM334 (230 V AC, 8xFO): before V3.2 — fixed in V3.2
- Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+): before V3.2 — fixed in V3.2
- Siemens SCALANCE XRM334 (24 V DC, 12xFO): before V3.2 — fixed in V3.2
- Siemens SCALANCE XRM334 (24 V DC, 8xFO): before V3.2 — fixed in V3.2
- Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+): before V3.2 — fixed in V3.2
- Siemens SCALANCE XRM334 (2x230 V AC, 12xFO): before V3.2 — fixed in V3.2
- Siemens SCALANCE XRM334 (2x230 V AC, 8xFO): before V3.2 — fixed in V3.2
- Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+): before V3.2 — fixed in V3.2
How to fix
Upgrade to a fixed version: Siemens RUGGEDCOM RST2428P V3.2; Siemens SCALANCE XCH328 V3.2; Siemens SCALANCE XCM324 V3.2; Siemens SCALANCE XCM328 V3.2; Siemens SCALANCE XCM332 V3.2; Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) V3.2; Siemens SCALANCE XRM334 (230 V AC, 12xFO) V3.2; Siemens SCALANCE XRM334 (230 V AC, 8xFO) V3.2; Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) V3.2; Siemens SCALANCE XRM334 (24 V DC, 12xFO) V3.2; Siemens SCALANCE XRM334 (24 V DC, 8xFO) V3.2; Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) V3.2. Check the vendor advisory for mitigations.
References
Get alerted when CVE-2025-40567 or the next vulnerability affects your stack