What’s Vulnerable › Vulnerabilities
CVE-2025-40594
- Severity: critical (CVSS 9.8 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.2% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2025-09-09 · updated 2026-10-23
- Weakness: CWE-269
Description
A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.
Affected products
- Siemens Sinamics G220 Firmware: 6.4, 6.4-hf1
- Siemens Sinamics S200 Firmware: 6.4
- Siemens Sinamics S210 Firmware: 6.4, 6.4-hf1
References
Get alerted when CVE-2025-40594 or the next vulnerability affects your stack