What’s Vulnerable › Vulnerabilities
CVE-2025-59105: Unencrypted Flash Storage in dormakaba access manager
- Severity: high (CVSS 7.0 v4.0)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.1% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2026-01-26 · updated 2026-06-17
- Weakness: CWE-312
Description
With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database.
Affected products
- dormakaba Access Manager 92xx-k5: 92xx-K5: All versions
- dormakaba Access Manager 92xx-k7: 92xx-K7: <BAME 06.00
References
- https://r.sec-consult.com/dkaccess
- https://r.sec-consult.com/dormakaba
- https://www.dormakabagroup.com/en/security-advisories