What’s Vulnerable › Vulnerabilities
CVE-2025-64298: Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource
- Severity: high (CVSS 7.5 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.2% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2025-12-02 · updated 2026-09-25
- Weakness: CWE-732
Description
NMIS/BioDose V22.02 and previous version installations where the embedded Microsoft SQLServer Express is used are exposed in the Windows share accessed by clients in networked installs. By default, this directory has insecure directory paths that allow access to the SQL Server database and configuration files, which can contain sensitive data.
Affected products
- Mirion Biodose/Nmis: before 23.0 — fixed in 23.0
How to fix
Upgrade to a fixed version: Mirion Biodose/Nmis 23.0. Check the vendor advisory for mitigations.
References
Get alerted when CVE-2025-64298 or the next vulnerability affects your stack