CVE-2025-69426: Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded SSH Credentials RCE
- Severity: critical (CVSS 10.0 v4.0)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.4% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2026-01-09 · updated 2026-06-17
- Weakness: CWE-732
Description
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise.
Affected products
- RUCKUS Networks vRIoT IOT Controller: from 2.3.0.0 (GA) before 3.0.0.0 (GA); from 2.3.1.0 (MR) before 3.0.0.0 (GA); from 2.4.0.0 (GA) before 3.0.0.0 (GA) — fixed in 3.0.0.0 (GA)
How to fix
Upgrade to a fixed version: RUCKUS Networks vRIoT IOT Controller 3.0.0.0 (GA). Check the vendor advisory for mitigations.
References
- https://support.ruckuswireless.com/security_bulletins/336
- https://www.vulncheck.com/advisories/ruckus-vriot-iot-controller-hardcoded-ssh-credentials-rce