What’s Vulnerable › Vulnerabilities
CVE-2026-41125
- Severity: medium (CVSS 6.0 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.2% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2026-05-12 · updated 2026-10-13
- Weakness: CWE-89
Description
A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions), blueplanet gridsave 110 TL3-S (All versions < V3.92), blueplanet gridsave 137 TL3-S (All versions < V3.92), blueplanet gridsave 92.0 TL3-S (All versions < V3.92). Improper neutralization of special elements used in an sql command ('sql injection') in KACO Meteor server allows an authorized attacker to elevate privileges over a local network.
Affected products
- Siemens blueplanet 100 NX3 M8: all versions
- Siemens blueplanet 100 TL3 GEN2: all versions
- Siemens blueplanet 105 TL3: before V3.92 — fixed in V3.92
- Siemens blueplanet 105 TL3 GEN2: all versions
- Siemens blueplanet 110 TL3: before V3.92 — fixed in V3.92
- Siemens blueplanet 125 NX3 M10: all versions
- Siemens blueplanet 125 TL3: before V3.92 — fixed in V3.92
- Siemens blueplanet 125 TL3 GEN2: all versions
- Siemens blueplanet 137 TL3: before V3.92 — fixed in V3.92
- Siemens blueplanet 150 TL3: before V3.92 — fixed in V3.92
- Siemens blueplanet 150 TL3 GEN2: all versions
- Siemens blueplanet 155 TL3: before V3.92 — fixed in V3.92
- Siemens blueplanet 155 TL3 GEN2: all versions
- Siemens blueplanet 165 TL3: before V3.92 — fixed in V3.92
- Siemens blueplanet 165 TL3 GEN2: all versions
- Siemens blueplanet 87.0 TL3: before V3.92 — fixed in V3.92
- Siemens blueplanet 87.0 TL3 GEN2: all versions
- Siemens blueplanet 92.0 TL3: before V3.92 — fixed in V3.92
- Siemens blueplanet 92.0 TL3 GEN2: all versions
- Siemens blueplanet gridsave 110 TL3-S: before V3.92 — fixed in V3.92
- Siemens blueplanet gridsave 137 TL3-S: before V3.92 — fixed in V3.92
- Siemens blueplanet gridsave 92.0 TL3-S: before V3.92 — fixed in V3.92
How to fix
Upgrade to a fixed version: Siemens blueplanet 105 TL3 V3.92; Siemens blueplanet 110 TL3 V3.92; Siemens blueplanet 125 TL3 V3.92; Siemens blueplanet 137 TL3 V3.92; Siemens blueplanet 150 TL3 V3.92; Siemens blueplanet 155 TL3 V3.92; Siemens blueplanet 165 TL3 V3.92; Siemens blueplanet 87.0 TL3 V3.92; Siemens blueplanet 92.0 TL3 V3.92; Siemens blueplanet gridsave 110 TL3-S V3.92; Siemens blueplanet gridsave 137 TL3-S V3.92; Siemens blueplanet gridsave 92.0 TL3-S V3.92. Check the vendor advisory for mitigations.
References
Get alerted when CVE-2026-41125 or the next vulnerability affects your stack