What’s Vulnerable › Vulnerabilities

CVE-2026-80145: Lantronix Autonomous Out-of-Band Devices CLI Command Injection via set cifs password

Description

Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.

Affected products

How to fix

Upgrade to a fixed version: LANTRONIX EMG7500 9.7.0.1; LANTRONIX EMG8500 9.7.0.1; LANTRONIX SLC8000 9.7.0.2; LANTRONIX SLC9000 9.7.0.2. Check the vendor advisory for mitigations.

References

Get alerted when CVE-2026-80145 or the next vulnerability affects your stack