What’s Vulnerable › Vulnerabilities
CVE-2026-8031: PicoTronica e-Clinic Healthcare System ECHS API Endpoint patient-records missing authentication
- Severity: medium (CVSS 5.3 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.4% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2026-05-06 · updated 2026-10-26
- Weakness: CWE-287
Description
A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The exploit is now public and may be used. Upgrading to version 5.7.1 is sufficient to fix this issue. You should upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
Affected products
References
- https://docs.google.com/document/d/1FByC9x21c5503cQg6lkxjffIwWlEAHtHi_83vk2eUdk/edit?usp=sharing
- https://vuldb.com/submit/800781
- https://vuldb.com/vuln/361357
- https://vuldb.com/vuln/361357/cti
Get alerted when CVE-2026-8031 or the next vulnerability affects your stack