What’s Vulnerable › Vulnerabilities
CVE-2026-9143: Incorrect Conversion between Numeric Types in NI grpc-device due to missing range checks in CodeGen
- Severity: medium (CVSS 5.3 v3.1)
- Exploited in the wild: not listed in CISA KEV
- EPSS: 0.3% probability of exploitation in the next 30 days
- Public exploit or detection template: none known
- Published: 2026-06-19 · updated 2026-06-25
- Weakness: CWE-681
Description
There is an incorrect conversion between numeric types vulnerability in NI grpc-device due to missing range checks in CodeGen. This may silently discard high bits if a size value exceeded the target type's range. This affects NI grpc-device 2.17.0 and prior versions.
Affected products
- NI InstrumentStudio: through 2025; 2026-q1, 2026-q2
- Ni Grpc Device Server: before 2.18.0 — fixed in 2.18.0
How to fix
Upgrade to a fixed version: Ni Grpc Device Server 2.18.0. Check the vendor advisory for mitigations.
References
- https://github.com/ni/grpc-device/security/advisories/GHSA-rhh6-fvjv-8m84
- https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/2026/multiple-vulnerabilities-in-ni-grpc-device-server.html
Get alerted when CVE-2026-9143 or the next vulnerability affects your stack